您所在的位置:
作者:Kuan-Yu Chen
单位:National Taiwan University

摘要

Background

Alzheimer’s disease (AD) and cerebral amyloid angiopathy (CAA) are both characterized by amyloid-β deposition but differ in their pathological distribution and clinical implications. Identifying disease-related imaging signals not dependent on visually apparent hemorrhage (e.g. dynamic amyloid PET) may provide complementary information beyond conventional late-frame uptake for distinguishing the two conditions.

Aim

This study aimed to identify features from dynamic [11C]-Pittsburgh compound B (PiB) PET for differentiating AD from CAA.

Methods

61 patients with AD or CAA, with the non-hemorrhagic hemisphere of their dynamic PiB PET data retained, were analyzed. Frame-wise PET uptake normalized to the pons was evaluated across cortical regions to characterize time-dependent signal differences between AD and CAA. Simplified Reference Tissue Model (SRTM) analysis with the pons as the reference region was additionally performed to derive relative tracer delivery (R1) and non-displaceable binding potential (BPnd). Discriminative performance of the PET-derived features was evaluated using receiver operating characteristic (ROC) analysis and quantified by the area under the curve (AUC).

Results

The posterior cingulate cortex (PCC) showed the most consistent dynamic PET discrimination between AD and CAA, particularly between 4 and 10 minutes after tracer injection. PCC 4–10 min uptake in the retained hemisphere and the PCC-to-global cortical uptake ratio achieved single-feature AUCs of approximately 0.67 and 0.69, respectively. Among the prespecified kinetic features, PCC R1 showed the strongest exploratory group signal and was moderately associated with the dynamic PCC 4–10 min uptake. This association suggests that the early-to-mid PCC signal contains a substantial tracer-delivery or perfusion-like component, whereas BPnd showed little group discrimination.

Conclusions

Early-to-mid dynamic PiB PET contains useful information for differentiating AD from CAA; the PCC 4–10 min signal showed the most consistent discrimination. These findings support further investigation of dynamic PET features as complementary imaging markers for AD–CAA differentiation.

相关会议

更多
“医”路携手,“药”有作为一基层抗感染系列学术研讨会(3)
2026-11-30
北京
重庆市医师协会器官移植医师分会2026年学术年会
2026-11-30
待定

相关直播

更多
第八届上海国际癌症大会
2026-06-03
上海静安英迪格酒店
观看回放
产前咨询
2026-09-01
产前咨询
观看回放
冠心病及腔内影像生理学规范诊疗系列课程:左心室血栓的诊疗新进展
2026-11-17
阜外医院冠心病一病区
观看回放

最新视频

更多
糖尿病分型诊断中国专家共识解读
徐静
西安交通大学第二附属医院
李宗恩授课
李宗恩
病例分享
王攀霞
喀什市人民医院
高脂血症与急性胰腺炎
高静
新疆医科大学第五附属医院